Filter Results By:

Products

Applications

Manufacturers

Showing results: 121 - 135 of 144 items found.

  • Handheld TDR / Cable Fault Locator

    RapidTrace 1100 - Vonaq Ltd

    *This TDR / Cable Fault Locator is suitable for testing all Communication CAT (3-6) , Power Cabling , coaxial and mains power cabling*The RapidTrace 1100 TDR / Cable Fault Locator has a 11 measurement ranges from 0.5m to 3500m (3.5km) and is accurate to 1%*The TDR / Cable Fault Locator has 25, 50, 75 & 100ohm Selectable Cable Impedances*Using pre determined gain and pulse width on the TDR / Cable Fault Locator, all major operating and setting parameters can be easily accessed

  • SparkFun LED Driver Breakout

    LP55231 - SparkFun Electronics

    The SparkFun LP55231 LED Driver Breakout is a self-contained solution for developing and deploying the nine-channel I2C LED controller. Remarkably simple, the breakout is equipped primarily with just the LP55231 LED controller IC, plus three RGB LEDs. It also features pads and jumpers for replacing the onboard LEDs with external ones, and configuring the I2C bus, which allows you to daisy-chain up to four LP55231s. This breakout drives the LEDs using Pulse Width Modulation (PWM), so it is well-suited for variable intensity and color-mixing applications!

  • PC/104 SBC with Vortex86DX3 1GHz CPU and Data Acquisition

    HELIX - Diamond Systems Corp

    The HELIX family of PC/104 SBCs combines mid-range CPU performance, standard PC I/O, and on-board data acquisition circuitry in a compact size and at a competitive price. Available PC I/O includes 3 or 6 USB 2.0 (model dependent), 4 serial ports (2 RS-232/422/485 and 2 RS-232), 1 10/100Mbps Ethernet, 1 Gigabit Ethernet, and a SATA port. The optional data acquisition circuit includes 16 16-bit analog inputs, 4 16-bit analog outputs and 27 digital I/O lines configurable as counter/timers and pulse width modulators.

  • Aspirated Radiation Shield

    Apogee Instruments, Inc.

    The fan has an ingress protection (IP) rating of 55, virtually eliminating moisture and dust ingress. At full speed the power requirement is 1 W (80 mA at 12 V DC). To conserve power fan speed can be reduced, via pulse width modulation (PWM), to 0.3 W at night or when wind speed is greater than 3 m s-1 without loss of accuracy. If the fan is continuously operated at full speed lifetime is rated at 50,000 hours (5.7 years). The fan includes a tachometer, allowing RPM to be mounted to detect obstruction of the fan.

  • JESD22-A115 Machine-Model (MM) Pulse Emulator

    MM-10A - High Power Pulse Instruments GmbH

    - Pulse unit to generate JESD22-A115 machine-model (MM) waveforms with TLP- Extremely stable and reproducible machine-model (MM) waveforms- Compatible with HPPI TLP-3010C/4010C/8010A/8010Csystems which have installed pulse width of 25 ns and rise time of 100 ps to 300 ps- Up to ±10 A machine-model peak current with TLP-3010C, which is equivalent to ±667 V (MM)- Up to ±15 A machine-model peak current with TLP-4010C, which is equivalent to ±1000 V (MM)- Up to ±30 A machine-model peak current with TLP-8010A and TLP-8010C, which is equivalent to ±2000 V (MM)- Same measurement procedure as TLP including DC test of the DUT- Compatible with HPPI TLP software and waveform data storage and management- 50 Ω SMA input and output connectors- Compact size: 61 mm x 25 mm x 17 mm

  • AC Calibration Standard

    1U647-001 - Sigma Tek, Inc.

    The 1U647-001 is a low cost calibration standard used to determine if a 1U632-100 or a 1U663-100 DMU requires factory calibration. Its portability makes it ideal for field-testing. The standard generates signals that simulate the aircraft’s resolvers, rotary variable transformers (RVTs), and linear variable displacement transformers (LVDTs). The unit also generates a pulse width modulated (PWM) signal, and routes the output of an ARINC 429 source to the different DMU input channels. The calibration standard connects directly to the DMU and replaces the output signals of an active extender card. Discrete switch settings simplify testing. The unit is housed in a rugged aluminum case.

  • Photometer

    Optronik Line DSP 200 - Instrument Systems Optische Messtechnik GmbH

    DSP 200 offers outstanding sensitivity and stability for precise measurements even at very low illumination levels. The instrument meets, of course, all requirements of the newest standards, like EN 13032-1 and DIN 5032-7 (2017). A low-noise photo diode with V(lambda)-filtering and optimized electronics provides for a broad dynamic range from 0.1 mlx to 200 klx. At the same time the very high local resolution allows an accurate determination even of high gradients when measuring headlamps. Therefore, the DSP 200 is suitable for all automotive and traffic applications, as well as for flashlights and for measurements of all pulse width modulated light sources.

  • Laser Distance Meters

    Zhuhai Measure Science and Technology Co. Ltd

    Laser Distance Meter is a hand tool to get the range for 2 points. A Laser Distance Meter sends a pulse of laser light to the target and measures the time it takes for the reflection to return. The range is 0.05--20/40/60/80/100 meters and the accuracy is 1.5 mm. On-board processing allows the device to add, subtract,calculate areas and volumes and to triangulate. You can measure length width and height, volume, area, the Pythagorean theorem, self-leveline measuring , auto vertical measuring , measuring distance between every 2 points. Compare with the traditional tape, a Laser Distance Meter wins on every count: speed , accuracy, safety, versatility, convenience and functionality.

  • TX Ranger

    4405200 - BI Communications

    The TX Ranger is a hand-held Time Domain Reflectometer (cable fault locator) with a first range of 2.5 meters combined with a 1.3 Nano second pulse width gives a blind zone of only 5 cm, it makes this the ideal product for fault location on short cable assemblies and harnesses. Small and intermittent faults can be easily identified by using the selectable gain control allowing trace amplification of up to 7 times and when set to scan lock mode the advanced noise reduction software may be selected allowing the user to select between 8,16 and 32-point trace averaging further enhancing the clarity of the trace by reducing electrical and environmental interference.

  • Handheld Digital Multimeter, 4.5 digit, up to 800 hours battery life

    U1282A - Keysight Technologies

    60,000 counts resolution on dual display0.025% basic DC voltage accuracy Longer battery life up to 800 hours Certified to IP 67 for dust and water protection Tested to withstand a 3-meter (10-ft) drop Programmable via USB (Download Programming Guide here)CAT III 1000 V/ CAT IV 600 V overvoltage protection Vsense for non-contact voltage detection Square wave output for generating pulse width modulation (PWM) signal Frequency counter Low pass filter

  • Automatic Double Drop Test Machine

    DT-JT - Lisun Electronics Inc.

    The machine wills automatic stop positioning after sample reach up to the sated height position. According to the different size to choice the test distance between tests arms, electric pulse width. The release mechanism of machine are flexible and reliable, to ensure the sample without any external influence during the release of instant and free fall way, and make sure it meet sample’s dropping requirements. It is according to GB4757.5-84), GB/T4857.5-92,  GB/T2423.5, IEC68-2-27, JISZ0202-87, ISO2248-19, ISO2248-1985(E, ASTMD5276-1998 and ISTA3A. This series drop test bench for measuring the main simulation packages in the transportation, loading and unloading process under drop impact influence, identification package impact strength and packaging design.

  • 4 Channel 1.0 ~ 17.0 Gb/s Pulse Pattern Generator and Error Detector

    CA9806 - UC Instruments, Corp.

    The UC INSTRUEMNTS CA9806 is a high performance, flexible four channel Pulse Pattern Generator and Error Detector that can operate from 1.0 to 17.0 Gb/s (consult factory for higher or lower operation speeds). It is also a standalone Bit Error Rate test solution that incorporates an internal full rate clock synthesizer. Its small size allows it to be placed close to the device under test, it can also be placed further away using the TX driver pre and post emphasis controls features to compensate for cable and interconnect losses. It also has a non destructive, integrated eye outline capture feature along with a quick eye height and width measurement capability. Build‐in 8.5 ~ 15 Gb/s eye diagram testing function.

  • Function Generators

    C&C Instruments Co.

    Waveform : Sine, Triangle, Square, Pulse, Sawtooth, Ramp 0.2Hz-150MHz EXT Frequency Counter(Option : 1:6 GHz or 2.7GHz) Self made insert ASIC Function : Total, RPM, Period, LPF, COUPL(AC/DC), ATT(X10) Fast,High-Resolution, 8Digits LED display Internal or External AM,FM Modulation Internal or External Burst and Linear Sweep Countrol from 1 : 1 to 100:1 TTL/CMOS Leveled Square Wave Output Maximum Attenuation of 20 dB cna be obtained Output impedance : 50 INPUT SENSITMTYKHz Range : 100mVms, MHz Range : 300mVms SWEEP WIDTH : Variable from 1:1 -100:1 RATE : 0.5Hz - 50Hz(20ms-2s) INTERNAL : Linear Bilt-in 5digits Green LED display

  • Integrated I-V Test Systems

    OAI

    The OAI Integrated I-V Test System is perfect for R&D as well as production, the OAI Integrated I-V Test System delivers extremely accurate solar cell performance measurement. OAI’s advanced fully Integrated I-V Test System is designed to overcome the limitations of flash testing by providing a highly optimized pulse width and voltage sweep rate to match any type of solar cell’s high capacitance and slow dielectric response speed. As a result, the system produces extremely accurate measurements of solar cell I-V parameters and efficiency while leading to the most accurate test results.

  • Semiconductor Optical Amplifier

    SOA - Amonics Ltd.

    Amonics SOA is a polarization maintaining optical amplifier with high fiber-to-fiber gain. It is designed for transmitter applications to increase optical launch power to compensate for the loss of other optical devices. The benchtop version incorporates a user-friendly front panel housing a LCD monitor display, key switch, power control knob and optical connectors. RS232 computer interface is also equipped on the rear panel. 1MHz with 10ns pulse width intensity modulation is available. The OEM module version is an ideal building block for OEM system integration, especially in optical communication network and CATV applications. It requires only a single +5V power supply.

Get Help